Cell 10mm Spect T17 . ,Case Of 8
|
|
Details:
Here are the corrected product descriptions: **semi-micro, cat. No.: 414004-059** Cover type: stopper sample volume: 1.4 Ml pathlength: 10 mm external dimensions: w×l×h 12.5×12.5×40 Mm internal dimensions: w×l 4×10 mm manufactured from spectrosil quartz for accurate readings over the entire uv range to near infrared range. Due to the fully heat-fused construction (no intermediate materials or adhesives) and careful annealing to remove any strain, there is no optical or physical distortion of the two optically polished windows. **Semi-micro, cat. No.: 414004-060** Cover type: screw cap with septum sample volume: 1.4 Ml pathlength: 10 mm external dimensions: w×l×h 12.5×12.5×40 Mm internal dimensions: w×l 4×10 mm manufactured from spectrosil quartz for accurate readings over the entire uv range to near infrared range. Due to the fully heat-fused construction (no intermediate materials or adhesives) and careful annealing to remove any strain, there is no optical or physical distortion of the two optically polished windows. **Standard rectangular, cat. No.: 414004-061** Cover type: stopper sample volume: 3.5 Ml pathlength: 10 mm external dimensions: w×l×h 12.5×12.5×45 Mm internal dimensions: w×l 10×10 mm manufactured from spectrosil quartz for accurate readings over the entire uv range to near infrared range. Due to the fully heat-fused construction (no intermediate materials or adhesives) and careful annealing to remove any strain, there is no optical or physical distortion of the two optically polished windows. **Standard rectangular, cat. No.: 414004-062** Cover type: screw cap with gasket sample volume: 3.5 Ml pathlength: 10 mm external dimensions: w×l×h 12.5×12.5×45 Mm internal dimensions: w×l 10×10 mm manufactured from spectrosil quartz for accurate readings over the entire uv range to near infrared range. Due to the fully heat-fused construction (no intermediate materials or adhesives) and careful annealing to remove any strain, there is no optical or physical distortion of the two optically polished windows. **Standard rectangular, cat. No.: 414004-063** Cover type: screw cap with septum sample volume: 3.5 Ml pathlength: 10 mm external dimensions: w×l×h 12.5×12.5×45 Mm internal dimensions: w×l 10×10 mm manufactured from spectrosil quartz for accurate readings over the entire uv range to near infrared range. Due to the fully heat-fused construction (no intermediate materials or adhesives) and careful annealing to remove any strain, there is no optical or physical distortion of the two optically polished windows. **Micro, cat. No.: 414004-064** Cover type: flat lid sample volume: 0.7 Ml pathlength: 10 mm external dimensions: w×l×h 12.5×12.5×40 Mm internal dimensions: w×l 2×10 mm manufactured from spectrosil quartz for accurate readings over the entire uv range to near infrared range. Due to the fully heat-fused construction (no intermediate materials or adhesives) and careful annealing to remove any strain, there is no optical or physical distortion of the two optically polished windows. **Micro, cat. No.: 414004-065** Cover type: screw cap with gasket sample volume: 0.7 Ml pathlength: 10 mm external dimensions: w×l×h 12.5×12.5×40 Mm internal dimensions: w×l 2×10 mm manufactured from spectrosil quartz for accurate readings over the entire uv range to near infrared range. Due to the fully heat-fused construction (no intermediate materials or adhesives) and careful annealing to remove any strain, there is no optical or physical distortion of the two optically polished windows. **Micro, cat. No.: 414004-066** Cover type: screw cap with septum sample volume: 0.7 Ml pathlength: 10 mm external dimensions: w×l×h 12.5×12.5×40 Mm internal dimensions: w×l 2×10 mm manufactured from spectrosil quartz for accurate readings over the entire uv range to near infrared range. Due to the fully heat-fused construction (no intermediate materials or adhesives) and careful annealing to remove any strain, there is no optical or physical distortion of the two optically polished windows. **Far uv quartz** wavelength range: 170-2700 nm matched sets available fully heat-fused construction note: not recommended for use with ultrasonic cleaning.
Additional Information
| SKU | 23269417 |
|---|---|
| UOM | Case of 8 |
| UNSPSC | 41121813 |
| Manufacturer Part Number | 414004-076 |
| Product Dimensions | 8X6X2 Inches |
| Product Weight | 0.8 |
